Type of registered services provided, Service order code, T1 channel assignment – AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual

Page 428: Csu/dsu requirements, Service parameters/request information for pri

Advertising
background image

Appendix B: Required Service Parameters

412

MaxCS 7.5 Administration Manual

DNIS, Caller ID:

DTMF (Dual Tone Multi-Frequency)

Physical Termination:

RJ-48X or RJ-48C

Wire:

4 wires

800 Service:

You decide

Termination Impedance:

100 ohms

Type of Registered Services Provided

BN 1.544 Mbps SF without power

DN 1.544 Mbps SF B8ZS without power

1KN 1.544 Mbps ANSI ESF without power

1SN 1.544 Mbps ANSI ESF, B8ZS without power (recommended)

Service Order Code

SOC 6.0P AS.2

T1 Channel Assignment

Trunk Type – In, Out, or 2-Way (recommended)

Channels Assigned – 24 (Enter partial channels if you wish to subscribe to both voice and data service.)

Hunting – Most Idle, Least Idle, Ascend, Descend

DNIS Digits/Signal – 3/DTMF (can be 3 to 10 digits)

Caller ID Signal – DTMF, if available (Not every service provider provides Caller ID over T1 lines.)

CSU/DSU Requirements

The CSU (channel service unit) is a device used to connect a digital trunk line coming in from the phone
company to the PBX. A CSU can terminate signals, repeat signals and respond to loopback commands sent
from the central office.

Service Parameters/Request Information for PRI

To subscribe to PRI service, certain parameters are required to establish service. The information provided
below identifies the recommended and supported parameters for PRI service. When ordering PRI service, pro-
vide the following service request information:

Equipment Information

PBX Manufacturer – AltiGen Communications, Inc.

CSU/DSU – ADTRAN T1 ACE (recommended) or other CSU/DSU

Advertising