Nxp semiconductors – NXP Semiconductors LPC24XX UM10237 User Manual

Page 359

Advertising
background image

UM10237_4

© NXP B.V. 2009. All rights reserved.

User manual

Rev. 04 — 26 August 2009

359 of 792

NXP Semiconductors

UM10237

Chapter 13: LPC24XX USB device controller

9.8.14 USB New DD Request Interrupt Clear register (USBNDDRIntClr - 0xFFE0

C2B0)

Writing one to a bit in this register clears the corresponding bit in the USBNDDRIntSt
register. Writing zero has no effect. USBNDDRIntClr is a write only register.

9.8.15 USB New DD Request Interrupt Set register (USBNDDRIntSet - 0xFFE0

C2B4)

Writing one to a bit in this register sets the corresponding bit in the USBNDDRIntSt
register. Writing zero has no effect. USBNDDRIntSet is a write only register

9.8.16 USB System Error Interrupt Status register (USBSysErrIntSt - 0xFFE0 C2B8)

If a system error (AHB bus error) occurs when transferring the data or when fetching or
updating the DD the corresponding bit is set in this register. USBSysErrIntSt is a read only
register.

9.8.17 USB System Error Interrupt Clear register (USBSysErrIntClr - 0xFFE0 C2BC)

Writing one to a bit in this register clears the corresponding bit in the USBSysErrIntSt
register. Writing zero has no effect. USBSysErrIntClr is a write only register.

Table 342. USB New DD Request Interrupt Clear register (USBNDDRIntClr - address 0xFFE0

C2B0) bit description

Bit

Symbol

Value

Description

Reset value

31:0 EPxx

Clear endpoint xx (2

xx

31) new DD interrupt request. 0

0

No effect.

1

Clear the EPxx new DD interrupt request in the
USBNDDRIntSt register.

Table 343. USB New DD Request Interrupt Set register (USBNDDRIntSet - address 0xFFE0

C2B4) bit description

Bit

Symbol

Value

Description

Reset value

31:0

EPxx

Set endpoint xx (2

xx

31) new DD interrupt request.

0

0

No effect.

1

Set the EPxx new DD interrupt request in the
USBNDDRIntSt register.

Table 344. USB System Error Interrupt Status register (USBSysErrIntSt - address

0xFFE0 C2B8) bit description

Bit

Symbol

Value

Description

Reset
value

31:0

EPxx

Endpoint xx (2

xx

31) System Error Interrupt request.

0

0

There is no System Error Interrupt request for endpoint xx.

1

There is a System Error Interrupt request for endpoint xx.