Ails see, Nxp semiconductors – NXP Semiconductors LPC24XX UM10237 User Manual

Page 456

Advertising
background image

UM10237_4

© NXP B.V. 2009. All rights reserved.

User manual

Rev. 04 — 26 August 2009

456 of 792

NXP Semiconductors

UM10237

Chapter 17: LPC24XX UART1

4.11 UART1 Line Status Register (U1LSR - 0xE001 0014, Read Only)

The U1LSR is a read-only register that provides status information on the UART1 TX and
RX blocks.

Table 408. UART1 Line Status Register (U1LSR - address 0xE001 0014, Read Only) bit

description

Bit Symbol

Value Description

Reset
Value

0

Receiver
Data
Ready
(RDR)

0

U1LSR[0] is set when the U1RBR holds an unread character and
is cleared when the UART1 RBR FIFO is empty.

0

U1RBR is empty.

1

U1RBR contains valid data.

1

Overrun
Error
(OE)

0

The overrun error condition is set as soon as it occurs. An U1LSR
read clears U1LSR[1]. U1LSR[1] is set when UART1 RSR has a
new character assembled and the UART1 RBR FIFO is full. In
this case, the UART1 RBR FIFO will not be overwritten and the
character in the UART1 RSR will be lost.

0

Overrun error status is inactive.

1

Overrun error status is active.

2

Parity
Error
(PE)

0

When the parity bit of a received character is in the wrong state, a
parity error occurs. An U1LSR read clears U1LSR[2]. Time of
parity error detection is dependent on U1FCR[0].

Note:

A parity error is associated with the character at the top of

the UART1 RBR FIFO.

0

Parity error status is inactive.

1

Parity error status is active.

3

Framing
Error
(FE)

0

When the stop bit of a received character is a logic 0, a framing
error occurs. An U1LSR read clears U1LSR[3]. The time of the
framing error detection is dependent on U1FCR0. Upon detection
of a framing error, the RX will attempt to resynchronize to the data
and assume that the bad stop bit is actually an early start bit.
However, it cannot be assumed that the next received byte will be
correct even if there is no Framing Error.

Note:

A framing error is associated with the character at the top

of the UART1 RBR FIFO.

0

Framing error status is inactive.

1

Framing error status is active.

4

Break
Interrupt
(BI)

0

When RXD1 is held in the spacing state (all 0’s) for one full
character transmission (start, data, parity, stop), a break interrupt
occurs. Once the break condition has been detected, the receiver
goes idle until RXD1 goes to marking state (all 1’s). An U1LSR
read clears this status bit. The time of break detection is
dependent on U1FCR[0].

Note:

The break interrupt is associated with the character at the

top of the UART1 RBR FIFO.

0

Break interrupt status is inactive.

1

Break interrupt status is active.