Chapter 4: LPC24XX Clocking and power control

M = (F

CCO

× N) / (2 × F

IN

)

The smallest frequency for F

CCO

that can produce our desired CPU clock rate and is

within the PLL operating range is 288 MHz (4

× 72 MHz). Start by assuming N = 1, since

this produces the smallest multiplier needed for the PLL.

So, M = 288

Ч 10

6

/ (2

Ч 32,768) = 4,394.53125. This is not an integer, so the CPU

frequency will not be exactly 288 MHz with this setting. Since this case is less obvious, it
may be useful to make a table of possibilities for different values of N (see

Table 4–52

).

Beyond N = 7, the value of M is out of range or not supported, so the table stops there. In
the table, the calculated M value is rounded to the nearest integer. If this results in CCLK
being above the maximum operating frequency (72 MHz), it is allowed if it is not more than
1/2

% above the maximum frequency.

In general, larger vlaues of F

REF

result in a more stable PLL when the input clock is a low

frequency. Even the first table entry shows a very small error of just over 1 hundredth of a
percent, or 107 parts per million (ppm). If that is not accurate enough in the application,
the second case gives a much smaller error of 7 ppm.

Remember that when a frequency below about 1 MHz is used as the PLL clock source,
not all multiplier values are available. As it turns out, all of the rounded M values found in

Table 4–52

of this exmaple are supported, as may be confirmed in

Table 4–51

.

If PLL calculations suggest use of unsupported multiplier values, those values must be
disregarded and other values examined to find the best fit. Multiplier values one count off
from calculated values may also be good possibilities..

The value written to PLLCFG for the second table entry would be 0x12254
(N - 1 = 1 = 0x1; M - 1 = 8788 = 0x2254).

3.2.14 PLL setup sequence

The following sequence must be followed step by step in order to have the PLL initialized
an running:

1. Disconnect the PLL with one feed sequence if PLL is already connected.

2. Disable the PLL with one feed sequence.

3. Change the CPU Clock Divider setting to speed up operation without the PLL, if

desired.

4. Write to the Clock Source Selection Control register to change the clock source.

5. Write to the PLLCFG and make it effective with one feed sequence. The PLLCFG can

only be updated when the PLL is disabled.

Table 52.

Potential values for PLL example

N

M

M Rounded

F

REF

(Hz)

F

CCO

(MHz)

Actual
CCLK (MHz)

% Error

1

4394.53125

4395

32768

288.0307

72.0077

0.0107

2

8789.0625

8789

16384

287.9980

71.9995

-0.0007

3

13183.59375

13184

10922.67

288.0089

72.0022

0.0031

4

17578.125

17578

8192

287.9980

71.9995

-0.0007

5

21972.65625

21973

6553.6

288.0045

72.0011

0.0016