3 oscillator fault detection, Figure 7–5. oscillator-fault-interrupt – Texas Instruments MSP430x1xx User Manual

Page 106

Advertising
background image

LFXT1 and XT2 Oscillators

7-6

7.2.3

Oscillator Fault Detection

An analog circuit controls the operation of oscillators LFXT1 and XT2 and flags
an oscillator fault when approximately 100 cycles (at 1 MHz) of the crystal are
missed. The active OSCFault signal sets the oscillator-fault-interrupt flag
(OFIFG) and requests a non-maskable interrupt when the oscillator-fault inter-
rupt enable bit (OFIE) is set. User software must clear the OFIFG flag.

Figure 7–5. Oscillator-Fault-Interrupt

XT_OscFault

S

Clear

NMIFG

NMIRS

OFIFG

OFIE

PUC

IRQA

IE1.1

IFG1.1

XT1off

LFXT1_OscFault

POR

XT2off

XT2_OscFault

XT2

Oscillator Fault NMI

Fault_from

XT2

Fault_from

XT1

XTS

SELM.1

SELM.0

DCOR

Select DCO including Internal Resistor XT Oscillator Fails

XT2 Is an internal signal
XT2 = 0: Two oscillators – MSP430x11x and MSP430x11x1 devices
XT2 = 1: Three oscillators – MSP430F13x and MSP430F14x devices
IRQA: Interrupt request accepted

XSELM.1

XDCOR

The XT2_OscFault signal of the XT2 oscillator, and the LFXT1_OscFault sig-
nal of the LFXT1 oscillator will set the oscillator-fault-interrupt flag (OFIFG) in-
dependently

.

During two-oscillator implementation, the oscillator-fault-inter-

rupt flag can be reset by software if the LFXT1_OscFault signal is a logic low.
During three-oscillator implementation, the oscillator-fault-interrupt flag can
be reset by software only if both oscillator-fault signals, LFXT1_OscFault and
XT2_OscFault, are low.