Timer Modes

11-10

Figure 11–8. New Period < Old Period

TBCL0old = 5
TBCL0new = 2

Timer

Register

5
4
3
2

1
0

0 1 2 3 4 5 0 1 2 3 0 1 2 0 1 2 0 1

5

2

0 1 2 3 4 5 0 1 2 3 4 0 1 2 0 1 2 0 1

5

2

Timer

Register

5
4
3
2

1
0

TBCL0old = 5
TBCL0new = 2

TBCL0

TBCL0

TBCL0 Loaded With 2 During High Clock Phase

TBCL0 Loaded With 2 During Low Clock Phase

Timer Clock

Timer

TBCL0

Timer Clock

Timer

TBCL0

n

0 or n–1†

TBCLold

TBCLnew

TBCLold

TBCLnew

n

n+1

0 or n†

Load New TBCL0

During High Phase of Clock

Load New TBCL0

During Low Phase of Clock

Up mode: 0; up/down mode: n–1

Up mode: 0; up/down mode: n

11.3.3 Timer—Continuous Mode

The continuous mode is used if the timer period of TBR

(max)

clock cycles is

used for the application. A typical application of the continuous mode is to
generate multiple, independent timings. In continuous mode, the capture/
compare block 0 works in the same way as the other capture/compare blocks.

The capture/compare blocks and different output modes of each output unit
are useful to capture timer data based on external events or to generate
various different types of output signals. Examples of the different output
modes used with timer-continuous mode are shown in Figure 11–25.

In continuous mode, the timer starts counting from its present value. The
counter counts up to TBR

(max)

and restarts by counting from zero as shown

in Figure 11–9.

The maximum value of TBR [TBR

(max)

] in continuous mode is:

0FFFFh for 16-bit configuration
00FFFh for 12-bit configuration
003FFh for 10-bit configuration
000FFh for 8-bit configuration

Figure 11–9. Timer Continuous Mode