11.3.4 Timer—Up/Down Mode

The up/down mode is used if the timer period must be different from the
TBR

(max)

clock cycles, and if symmetrical pulse waveform generation is

needed. In up/down mode, the timer counts up to the content of compare latch
TBCL0, then back down to zero, as shown in Figure 11–12. The period is twice
the value in the TBCL0 latch.

Note:

If TBCL0 > TBR

(max),

the counter operates as if it were configured for

continuous mode. It will not count down from TBR

(max)

to zero.

Figure 11–12.Timer Up/Down Mode

0h

TBCL0

The up/down mode also supports applications that require dead times
between output signals. For example, to avoid overload conditions, two
outputs driving an H-bridge must never be in a high state simultaneously. In
the following example (see Figure 11–13), the t

dead

is:

t

dead

=

t

timer

×

(TBCL1 – TBCL3)=

With:

t

dead

Time during which both outputs need to be inactive

t

timer

Cycle time of the timer clock

TBCLx Content of compare latch x

Note:

The dead time is ensured by the ability to simultaneously load the compare
latches.

Figure 11–13.Output Unit in Up/Down Mode (II)

TBCL0

TBCL1

0h

TBIFG

EQU3

EQU1

Output Mode 6: PWM Toggle/Set

Output Mode 2: PWM Toggle/Reset

EQU0

EQU3

EQU1

EQU3

Dead Time

EQU1

EQU3

TBIFG

EQU1

EQU0

Interrupt Events