Texas Instruments MSP430x1xx User Manual

Page 82

Advertising
background image

Instruction Set Overview

5-18

5.3.1

Double-Operand Instructions

Figure 5–7 illustrates the double-operand instruction format.

Figure 5–7. Double Operand Instruction Format

B/W

D-Reg

15

0

Opcode

Ad

S-Reg

8

7

14

13

12

11

10

9

6

5

4

3

2

1

As

Table 5–15 describes the effects of an instruction on double operand
instruction status bits.

Table 5–15.Double Operand Instruction Format Results

Mnemonic

S-Reg, D-Reg

Operation

Status Bits

V

N

Z

C

MOV

src,dst

src –> dst

ADD

src,dst

src + dst –> dst

*

*

*

*

ADDC

src,dst

src + dst + C –> dst

*

*

*

*

SUB

src,dst

dst + .not.src + 1 –> dst

*

*

*

*

SUBC

src,dst

dst + .not.src + C –> dst

*

*

*

*

CMP

src,dst

dst – src

*

*

*

*

DADD

src,dst

src + dst + C –> dst (dec)

*

*

*

*

AND

src,dst

src .and. dst –> dst

0

*

*

*

BIT

src,dst

src .and. dst

0

*

*

*

BIC

src,dst

.not.src .and. dst –> dst

BIS

src,dst

src .or. dst –> dst

XOR

src,dst

src .xor. dst –> dst

*

*

*

*

*

The status bit is affected

The status bit is not affected

0

The status bit is cleared

1

The status bit is set

Note:

Instructions CMP and SUB

The instructions CMP and SUB are identical except for the storage of the
result. The same is true for the BIT and AND instructions.