LFXT1 and XT2 Oscillators

7-7

Basic Clock Module

After applying V

CC

the oscillator fault signal (XT_OscFault) becomes active.

The XT_OscFault signal becomes inactive when XT2CLK and/or LFXT1CLK
begin oscillating, which takes approximately 50 clock cycles (at 1 MHz).

Figure 7–6. Oscillator-Fault Signal

V

CC

XT2CLK

LFXT1CLK

XT_OscFault

Oscillator

Start-Up

XT_OscFault becomes active after XT2CLK and/or LFXT1CLK stop oscillat-
ing. The delay associated with the XT_OscFault signal is approximately 50
clock cycles (at 1 MHz).

Figure 7–7. Oscillator Fault in Oscillator Error Condition

V

CC

XT2CLK

LFXT1CLK

XT_OscFault

Oscillator

Error

The oscillator-fault signal returns to a logic low if the oscillator starts operating
again. The delay is typically 50 clock cycles (at 1 MHz).

When an XT oscillator has stopped and is then restarted, the oscillator fault
signal (XT_OscFault) remains active until the oscillator starts operating, and
becomes inactive after a delay of typically 50 clock cycles at (1 MHz).