Timer Modes

11-16

11.4.1 Capture/Compare Block—Capture Mode

The capture mode is selected if the mode bit CAPx, located in control word
CCTLx, is set. The capture mode is used to fix time events. It can be used for
speed computations or time measurements. The timer value is copied into the
capture register (CCRx) with the selected edge (positive, negative, or both) of
the input signal. Captures may also be initiated by software as described in
section 11.4.1.1.

If a capture is performed:

-

The interrupt flag CCIFGx, located in control word CCTLx, is set.

-

An interrupt is requested if both interrupt enable bits CCIEx and GIE are
set.

The input signal to the capture/compare block is selected using control bits
CCISx1 and CCISx0, as shown in Figure 11–18. The input signal can be read
at any time by the software by reading bit CCIx.

Figure 11–18.Capture Logic Input Signal

Capture

Mode

CCISx0

CCISx1

CCIxA
CCIxB

GND

0

1

2

3

V

CC

CCMx1 CCMx0

Set_CCIFGx

0
0
1
1

0
1
0
1

Disabled
Positive Edge
Negative Edge
Both Edges

1

0

CAPx

CCIx

EQUx

CMAx

Synchronize

Capture

Timer
Clock

0

1

Capture

SCSx

The capture signal can also be synchronized with the timer clock to avoid race
conditions between the timer data and the capture signal. This is illustrated in
Figure 11–19. The bit SCSx in capture/compare control register CCTLx
selects the capture signal synchronization.

Figure 11–19.Capture Signal

n-2

Timer
Clock

Timer

Set

CCIFGx

Capture

ÎÎÎ

n+1

CCIx

n-1

n+2

n+3

n+4

n+5

n+6

n