Features for Low-Power Applications

7-17

Basic Clock Module

JNC

Retest

BIC.B

#OFIFG,&IFG1 ; Clear osc. fault int. flag

BIS.B

#(SELM1+SELM0),&BCSCTL2 ; Select now LFXT1 clock

Figure 7–15. Timing to Select Crystal Oscillator for MCLK, Example Uses LFXT1 in HF

Mode for MCLK

If Crystal Oscillator settled

Then Select Crystal Oscillator
for MCLK

DCOCLK

XT1CLK

MCLK

XT1CLK

DCOCLK

Turn on the

Crystal Oscillator

7.4.5

Synchronization of Clock Signals

The clock signals MCLK and SMCLK can be supplied by different clock
sources. While switching from one clock source to the other, the switch is syn-
chronized to avoid critical race conditions. When another clock source is se-
lected the following occurs in order:

1) The current clock cycle continues until the next rising edge.

2) The clock then remains high until the next rising edge of the newly selected

clock.

3) Now the new clock source is selected and continues with a full high period.

Figure 7–16. Select Another Clock Source Signal, Example Switches From DCOCLK to

LFXT1CLK for Clock MCLK

DCOCLK

LFXT1CLK

MCLK

LFXT1CLK

DCOCLK

Select

LFXT1CLK

Wait for

+LFXT1CLK