Texas Instruments MSP430x1xx User Manual

Page 278

Advertising
background image

Comparator_A in Applications

14-12

Figure 14–8. Timing for Temperature Measurement Systems

V

C

V

CC

0.25

×

V

CC

Phase I:

Charge-Up

Phase II:

Discharge C

Phase III:

Charge-Up

tref

Phase IV:

Discharge C

tmeas

t

R

meas

R

ref

MSP430 resources used to calculate the temperature sensed by R(meas):

Digital I/O:

-

Two digital outputs to charge and discharge the capacitor. Port pins are
set to provide a V

CC

output (charge a capacitor), reset to discharge a ca-

pacitor, and switched to high-impedance (including correct state of
CAPD.x bit) when not in use. One output discharges the capacitor via ref-
erence resistor R(ref), the other output discharges it via R(meas).

Comparator_A:

-

The – terminal is connected to a reference level, for example 0.25 x V

CC

.

-

The + terminal is connected to the positive terminal of the capacitor.

-

CAOUT or CAIFG utilized to measure the discharge time.

-

The output filter should be used to minimize multiple switching when the
voltages at the comparator inputs are close together.

If CAOUT is available as an input to a timer-capture register such as Timer_A,
the capacitor discharge time can be measured very precisely, without software
polling for a change of CAOUT, by using the timer capture function.

R

meas

+

R

ref

N

meas

N

ref

T

meas

+

ƒ

ǒ

R

meas

Ǔ