Control and Status Registers

12-20

calculation. The flag is disabled if parity generation and
detection are not enabled. In this case the flag is read as 0. It is
reset by a SWRST, a system reset, or by reading the URXBUF.

Bit 7:

The framing error flag bit FE is set when a character is received
with a 0 stop bit and is loaded into the receive buffer. Only the
first stop bit is checked when more than one is used. The missing
stop bit indicates that the start-bit synchronization is lost and the
character is incorrectly framed. FE is reset by a SWRST, a
system reset, or by reading the URXBUF.

Note:

Receive Status Control Bits

The receive status control bits FE, PE, OE, BRK, and RXWake are set by the
hardware according to the conditions of the characters received. Once the
bits are set, they remain set until the software resets them directly, or there
is a reading of the receive buffer. False character interpretation or missing-
interrupt capability can result in uncleared error bits.

12.5.4 Baud Rate Select and Modulation Control Registers

The baud-rate generator uses the content of the baud-rate select registers
UBR0 and UBR1 shown in Figure 12–19, with the modulation control register
to generate the serial data-stream bit timing.

Figure 12–19. USART Baud Rate Select Register

27

7

0

UBR00, 074h

26

25

24

23

22

21

20

rw

215

7

0

UBR10, 075h

214

213

212

211

210

29

28

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

rw

UBR01, 07Ch

UBR11, 07Dh

Baud rate =

BRCLK

UBR

)

1
n

S

n–1

i

+

0

mi

with UBR= [UBR1,UBR0]

The baud-rate control register range is:

3

UBR

<

0FFFFh

Note:

Unpredictable receive and transmission occur if UBR <3.

The modulation control register, shown in Figure 12–20, ensures proper timing
generation with the UBR0 and UBR01, even with crystal frequencies that are
not integer multiples of the required baud rate.

Figure 12–20. USART Modulation Control Register

7

0

UMCTL0, 073h

m5

m6

m4

m0

m3

m7

m1

m2

rw

rw

rw

rw

rw

rw

rw

rw

UMCTL1, 07Bh