Timer Modes

10-7

Timer_A

10.3 Timer Modes

10.3.1 Timer—Stop Mode

Stopping and starting the timer is done simply by changing the mode control
bits (MCx). The value of the timer is not affected.

When the timer is stopped from up/down mode and then restarted in up/down
mode, the timer counts in the same direction as it was counting before it was
stopped. For example, if the timer is in up/down mode and counting in the down
direction when the MCx bits are reset, when they are set back to the up/down
direction, the timer starts counting in the down direction from its previous
value. If this is not desired in an application, the CLR bit in the TACTL register
can be used to clear this direction memory feature.

10.3.2 Timer—Up Mode

The up mode is used if the timer period must be different from the 65,536
(16-bit) clock cycles of the continuous mode period. The capture/compare
register CCR0 data define the timer period.

The counter

counts up to the content of compare register CCR0, as shown in

Figure 10–5. When the timer value and the value of compare register CCR0
are equal (or if the timer value is greater than the CCR0 value), the timer
restarts counting from zero.

Figure 10–5. Timer Up Mode

0FFFFh

0h

CCR0

Flag CCIFG0 is set when the timer equals the CCR0 value. The TAIFG flag is
set when the timer

counts from CCR0 to zero. All interrupt flags are set

independently of the corresponding interrupt enable bit, but an interrupt is
requested only if the corresponding interrupt enable bit and the GIE bit are set.
Figure 10–6 shows the flag set cycle.

Figure 10–6. Up Mode Flag Setting

CCR0–1

CCR0

0h

1h

CCR0–1

CCR0

0h

1h

Timer
Clock

Timer

Set Flag

TAIFG

Set Flag

CCIFG0