199

5

Motor interface

5.7

V/f control (VFCplus)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal variables of the motor control (oscilloscope signals)

• The red numbers in brackets listed in the signal flow stand for internal variables of the motor

control, which you can record by means of the

Oscilloscope

for purposes of diagnostics and

documentation.

( 579)

No. Variable of the motor control

Meaning

(1)

Speed.dnSpeedSetpoint

Speed setpoint

(2)

Current.Current.dnActualMotorCurrent

Actual motor current

(3)

Current.dnActualQuadratureCurrent

Actual Q current

(4)

Speed.dnActualMotorSpeed

Current motor speed

(6)

Frequency.dnActualRotatingFieldFrequency Actual field frequency

(7)

Voltage.dnOutputQuadratureVoltage

Q voltage

(8)

Voltage.dnOutputDirectCurrentCtrl

D voltage

(9)

Voltage.dnActualMotorVoltage

Current motor voltage