C00159 | quick stop by (source), C00162 | masked error number, C00166 | error description – Lenze 9400 User Manual

Page 751: C00159, C00166, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

751

14

Parameter reference

14.2

Parameter list | C00159

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00159

C00162

C00166

Parameter | Name:

C00159 | Quick stop by (source)

Data type: BITFIELD_16

Index: 24416

d

= 5F60

h

Display area
0x0000

0xFFFF

Value is bit-coded:

Bit 0 Reserved
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Internal PLC
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00162 | Masked Error number

Data type: UNSIGNED_32

Index: 24413

d

= 5F5D

h

From software version V5.0

Display of the individual components of the error number shown in

C00168

.

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C00162/1

Module ID + error number

• As described in the chapter "

Error messages

".

C00162/2

Instance number

C00162/3

Error response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00166 | Error description

Data type: VISIBLE_STRING

Index: 24409

d

= 5F59

h

Error description for error number indicated in

C00168

Read access  Write access  RSP  PLC-STOP  No transfer

Scaling factor: 1

Character length: 64