5motor interface – Lenze 9400 User Manual
Page 235
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
235
5
Motor interface
5.10
Internal interfaces | "LS_MotorInterface" system block
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
MI_dnActualFlux_n
DINT
From V3.0
Actual flux value
MI_bFlyingSyncBusy
| BOOL
From V3.0
"Flying restart function active" status signal
Flying restart function ( 209)
TRUE Flying restart function is active
MI_bClampIsActive
| BOOL
From V3.0
Status signal "Clamping is active"
TRUE Clamping is active.
MI_bMagnetisationFinished
| BOOL
From V3.0
Status signal "Motor magnetisation is completed"
Note:
This bit is only supported in the SLVC control mode (sensorless vector control).
TRUE Motor magnetisation is completed.
Identifier
DIS code | data type
Value/meaning