35 Restart program

Carries out a reset (warm start).

• All variables except the RETAIN variables are reset to

their initialisation value.

• The situation corresponds to a power failure or

switching the controller off/on (warm start) while the

program is running.

36 Reset runtime measurement

Runtime measurement

41 Inhibit controller
42 Enable controller
43 Reset error
45 Activate quick stop

Basic function "

Quick stop

"

46 Reset quick stop

Basic function "

Quick stop

"

47 Internal command 47

For Lenze service only

48 Internal command 48

For Lenze service only

51 Identify pole position (360°)

Executes identification of pole position.

• The function can only be activated when the

controller is inhibited.

• After this, the execution of the command starts

automatically when the controller is enabled.

• During the pole position identification, the motor

carries out one electrical revolution. This leads to a

mechanical rotation of the motor shaft.

• The determined pole position is indicated under code

C00058

.

Pole position identification

52 Identify pole position (min. motion)

Executes identification of pole position.

• The function can only be activated when the

controller is inhibited.

• After this, the execution of the command starts

automatically when the controller is enabled.

• During the pole position identification, the rotor

aligns itself. This is compensated by a position

control.

• The determined pole position is indicated under code

C00058

.

Pole position identification

59 Resolver error identification

From software version V7.0

Execute resolver error identification.

Resolver error compensation

70 Load Lenze inverter characteristic

From software version V4.0

Load type-dependent inverter error characteristic.

• For the case that the determination of the inverter

error characteristic with the device command "71:

Determine inverter characteristic" was not possible or

has supplied incorrect results.

• The function can only be activated when the

controller is inhibited.

71 Calculate inv. characteristic

Determines inverter error characteristic.

• The function can only be activated when the

controller is inhibited.

• After this, the execution of the command starts

automatically when the controller is enabled.

Optimise the switching performance of the inverter

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_32

Index: 24573

d

= 5FFD

h