4drive interface – Lenze 9400 User Manual

Page 35

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

35

4

Drive interface

4.1

Machine parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

"Modulo" traversing range
The measuring system is repeated.

• If the cycle set in

C02536

is exceeded, a defined overflow occurs. In a rotative system, the cycle

typically corresponds to a revolution or tool distance.

• For positioning in the "Modulo" traversing range the home position must be known.
• Software limit positions are not effective.
• Absolute targets can be approached by exceeding the measuring system limit, e.g. from 10° to

350°.

[4-7]

Example: Modulo traversing range - "rotary table""

Dependencies - traversing range/basic drive functions

• The following table lists the different dependencies between the selected traversing range and

the basic drive functions.

C02536

: Cycle (illustration = 60°)

M

Œ

Basic drive function

Traversing range

Unlimited

Limited

Modulo

Position data for

Encoder evaluation

Continuously

Continuously

Clocked

Position data for

Position follower

Absolute

Absolute

Absolute (in time)

Positioning modes for

Positioning

1, 2, 5, 6, 7, 8

1, 2, 5, 6, 7, 8

5, 6, 11 ... 16

Restrictions for

Homing

None

None

Home position must

be in time

Limit positions (

Limiter

)

Permitted

Permitted

Not permitted

Example 1: Unlimited/limited position display

Reference setting

Position in the machine measuring system

Position in the motor measuring system

Example 2: Modulo position display

Cycle

Position in the machine measuring system

Position in the motor measuring system

Ž



Œ

j

t

Ž



Œ

j

t

Œ

Advertising
This manual is related to the following products: