C00309

C00310

C00311

Parameter | Name:

C00309 | Service code

Data type: UNSIGNED_32

Index: 24266

d

= 5ECA

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00310 | Service code

Data type: UNSIGNED_8

Index: 24265

d

= 5EC9

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00311 | CAN TPDO1 mask byte x

Data type: BITFIELD_8

Index: 24264

d

= 5EC8

h

A mask can be parameterised for each byte of the TPDO1 in the assigned subcode.

• In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.

• Mask "0x0" means that no bit of the corresponding byte actuates the transmission.

• Mask "0xff" means that every bit of the corresponding byte can actuate the transmission.

"CAN on board" system bus

Setting range
0x00

0xFF

Value is bit-coded:

Bit 0 Mask bit 0

... ...

Bit 7 Mask bit 7

Subcodes

Lenze setting

Info

C00311/1

0x00

Mask for byte 1 ... byte 8 of TPDO1

C00311/...
C00311/8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1