I-1801/1, 9"can on board" system bus – Lenze 9400 User Manual

Page 360

Advertising
background image

9

"CAN on board" system bus

9.10

Implemented CANopen objects | I-1801

360

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Subindex 3 - inhibit time
The delay time can only be changed if the PDO is inactive (subindex 1, bit 31 = 1). The entered value

multiplied by 0.1 results in the delay time in [ms]. The calculated delay time is always rounded down

to an inter value.
Example:

• Entered value: 26
• Calculated time = 26 * 0.1 [ms] = 2.6 [ms]  delay time = 2 [ms}

I-1801

Communication parameter for sending process data via TPDO2

• For assignment of the data telegram see object

I-1800

.

Index:

I-1801

Name:

TPDO2 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by TPDO

0x280 + node ID

0

4294967295 rw

U32

2: transmission type

254

0

255 rw

U8

3: inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: reserved

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

TPDO2 identifier

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x280 + node ID

C00320/2

2

TPDO transmission type according to DS301 V4.02

Transmission type ( 308)

C00322/2

3

Minimum time between sending two identical TPDOs

(see DS301 V4.02).

C00324/2

5

Cycle time for PDO transmission with transmission type

"254".

C00356/2