2 i/o status information, 3 control information, Control information – Lenze 9400 User Manual

Page 370: I/o status information ( 370), Control information ( 370), 10 safety engineering

Advertising
background image

10

Safety engineering

10.3

System block "LS_SafetyModuleInterface"

370

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3.2

I/O status information

Via the bit coded status signal SMI_dnIoState of the LS_SafetyModuleInterface SB, the SM3xx

safety module transmits the status of the safe inputs and outputs to the application.

• Which bits are supported depends on the safety module used.

Tip!
For decoding the status signal into individual boolean status signals, simply connect the

output SMI_dnIoState to the L_DevSMStateDecoderIO FB which is available in the function

library from V2.0.

10.3.3

Control information

Via the bit coded control signal SMI_dwControl of the LS_SafetyModuleInterface SB, the SM3xx

safety module transmits information on safety functions requested, or on active safety functions to

the application.

• Several safety functions can be requested/active at the same time.
• Which bits are supported depends on the safety module used.

Bit coding of the SMI_dnIoState status signal

Bit

Name

Meaning

0

SD-In1

Sensor input 1 in ON state.

1

SD-In2

Sensor input 2 in ON state.

2

SD-In3

Sensor input 3 in ON state.

3

SD-In4

Sensor input 4 in ON state.

5

AIS

Restart acknowledgement via terminal effected (negative edge: 10).

6

AIE

Error acknowledgement via terminal effected (negative edge: 10).

8

PS_AIS

Restart acknowledgement via safety bus effected (positive edge: 01)

9

PS_AIE

Error acknowledgement via safety bus effected (positive edge: 01)

12

SD-Out1

Safe output 1 (feedback output) in the ON state.

Bits not listed are reserved for future extensions!

Note!

The corresponding actions (e.g. braking, braking to standstill, holding of the standstill

position) must be executed by the application, e.g. via the basic function "

Limiter

".

( 502)

• To integrate the basic function "Limiter", the output SMI_dwControl is to be

connected to the input LIM_dwControl of the LS_Limiter system block.