11

Basic drive functions

11.14

Pole position identification

578

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Behaviour after mains ON

Behaviour after encoder error

Behaviour after resolver error

Initial situation 1

Behaviour after mains ON

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) = "1: SC: Servo control sync.

motor"

• Resolver - number of pole pairs (

C00080

) > 1

PPI_bPolePositionAvailable is only reset to FALSE if:

• Motor encoder selection (

C00495

) = "0: Resolver to

X7"

AND

• The number of motor pole pairs are (

C00059

no

integer multiple of the number of resolver pole pairs

(

C00080

).

Examples:
MSC motor

Motor - number of pole pairs = 4

Resolver - number of pole pairs = 1

The PPI_bPolePositionAvailable output is not reset to

FALSE.

Kuka motor

Motor - number of pole pairs = 4

Resolver - number of pole pairs = 4
Torque motor

Motor - number of pole pairs = 12

Resolver - number of pole pairs = 6

Initial situation 2

Behaviour after mains ON

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) = "1: SC: Servo control sync.

motor"

• Encoder type (

C00422

) =

• "0: Incremental encoder (TTL signal)" or

• "1: Sine/Cosine encoder"

• Motor encoder selection (

C00495

) = "1: Encoder to

X8"

PPI_bPolePositionAvailable is reset to FALSE.

Initial situation

Behaviour after encoder error

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) = "1: SC: Servo control sync.

motor"

• Encoder type (

C00422

) =

• "0: Incremental encoder (TTL signal)" or

• "1: Sine/Cosine encoder" or

• Motor encoder selection (

C00495

) = "1: Encoder to

X8"

PPI_bPolePositionAvailable is reset to FALSE.

Initial situation

Behaviour after resolver error

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) = "1: SC: Servo control sync.

motor"

• The number of motor pole pairs are (

C00059

no

integer multiple of the number of resolver pole pairs

(

C00080

).

• Motor encoder selection (

C00495

) = "0: Resolver to

X7"

PPI_bPolePositionAvailable is reset to FALSE.