C02775 | deceleration time, C02776 | time, C02779 | mol_setpointcurrent – Lenze 9400 User Manual

Page 893: C02780 | mol_dnstate, C02775/1, C02776/1, C02779, C02780, C02775/2, C02775/3

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

893

14

Parameter reference

14.2

Parameter list | C02775

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02775

C02776

C02779

C02780

Parameter | Name:

C02775 | Deceleration time

Data type: INTEGER_32

Index: 21800

d

= 5528

h

From software version V7.0

Basic function "

Manual jog open loop

"

Setting range

(min. value | unit | max. value)

0.001

s

2147483.647

Subcodes

Lenze setting

Info

C02775/1

1.000 s

Deceleration time 1

C02775/2

1.000 s

Deceleration time 2

C02775/3

1.000 s

Deceleration time 3

C02775/4

1.000 s

Deceleration time 4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02776 | Time

Data type: INTEGER_32

Index: 21799

d

= 5527

h

From software version V7.0

Basic function "

Manual jog open loop

"

Setting range

(min. value | unit | max. value)

0.001

s

2147483.647

Subcodes

Lenze setting

Info

C02776/1

1.000 s

Max. activation time 1

C02776/2

1.000 s

Max. activation time 2

C02776/3

1.000 s

Max. activation time 3

C02776/4

1.000 s

Max. activation time 4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02779 | MOL_SetpointCurrent

Data type: UNSIGNED_32

Index: 21796

d

= 5524

h

From software version V7.0

Maximum current of the selected profile parameter set.

Basic function "

Manual jog open loop

"

Display range

(min. value | unit | max. value)

0.00

A

42949672.95

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02780 | MOL_dnState

Data type: INTEGER_32

Index: 21795

d

= 5523

h

From software version V7.0

Status of the basic function "

Manual jog open loop

".

Display range

(min. value | unit | max. value)

-2147483648

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1