Negative limit switch has triggered [0x00b80002, 0x00b80003, 0x00b80004 – Lenze 9400 User Manual

Page 698: 0x00b80002, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

698

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Negative limit switch has triggered [0x00b80002]

Motor brake: Angular drift with closed brake too high [0x00b80003]

Motor brake: Automatically activated after waiting time has elapsed [0x00b80004]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The

travel range limit switch

in negative traversing

direction has tripped.

Reset fault message and

retract limit switch

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The stop position of the motor axis has changed by more

than the permissible angle of rotation set in

C02595

,

although the brake is engaged.

• Deactivate standstill monitoring (

C02595

= 0).

• Increase waiting time for status monitoring (

C02591

).

The standstill monitoring only starts after this

waiting time has elapsed.

• Increase brake closing time (

C02589

) since during the

brake closing time the standstill monitoring is not

active.

• Reduce threshold for brake activation (

C02581

).

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

4

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

This time monitoring will only be active if the speed

setpoint has reached the threshold for brake activation

(

C02581

).

If the actual speed value does not reach/fall below the

threshold set in

C02581

within the parameterised

waiting time for brake activation (

C02593

), the brake

will be closed due to time-out.

• Increase waiting time for brake activation (

C02593

).

• Reduce threshold for brake activation (

C02581

).

Advertising
This manual is related to the following products: