13 diagnostics & fault analysis, 7 error messages of the operating system – Lenze 9400 User Manual

Page 621

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

621

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x00680015

6815765

MXI1: Module has been changed

Information or warning locked if

the hardware type has also

changed.

-

0x0068000a

6815754

MXI1: Module is defective or missing

Fault

-

0x008c000d

9175053

MXI1: Module is missing or incompatible

Fault

-

0x008c000f

9175055

MXI1: PROFIBUS module is missing or incompatible

Fault

C00615/2

0x00680010

6815760

MXI1: Wrong module

System fault

-

0x008c0018

9175064

MXI2: CAN module is missing or incompatible

Fault

C00615/3

0x008c0014

9175060

MXI2: Digital frequency module is missing or incompatible

Fault

C00615/3

0x008c0012

9175058

MXI2: Ethernet module is missing or incompatible

Fault

C00615/3

0x008c0016

9175062

MXI2: ICM module is missing or incompatible

Fault

C00615/3

0x00680005

6815749

MXI2: Module changed during operation

Warning locked

-

0x00680016

6815766

MXI2: Module has been changed

Information or warning locked if

the hardware type has also

changed.

-

0x0068000b

6815755

MXI2: Module is defective or missing

System fault

-

0x008c000e

9175054

MXI2: Module is missing or incompatible

Fault

-

0x008c0010

9175056

MXI2: PROFIBUS module is missing or incompatible

Fault

C00615/3

0x00680011

6815761

MXI2: Wrong module

System fault

-

0x00b8000a

12058634

Negative direction of rotation limited

Information

C02716/1

0x00b80002

12058626

Negative limit switch has triggered

Quick stop by trouble

-

0x00b80008

12058632

Negative software limit switch overtravelled

Quick stop by trouble

C02716/2

0x006a0003

6946819

New applications loaded

Information

-

0x00910002

9502722

No heartbeat signal detected

System fault

-

0x0090000a

9437194

No parameters for module in MXI1

Fault

C00615/2

0x0090000b

9437195

No parameters for module in MXI2

Fault

C00615/3

0x007b0010

8060944

Overcurrent detected

Fault

-

0x00900000

9437184

Parameter set faulty

Fault

-

0x00900003

9437187

Parameter set loaded

Information

-

0x00900005

9437189

Parameter set restored

Fault

-

0x00900002

9437186

Parameter set saved

Information

-

0x00900009

9437193

Parameter set: type of standard device has been changed

Information

-

0x00900007

9437191

Parameter set: Version conflict

Fault

-

0x006a0015

6946837

PDO mapping (MXI1): Faulty configuration

Fault

-

0x006a0016

6946838

PDO mapping (MXI2): Faulty configuration

Fault

-

0x00b80000

12058624

PLC configuration invalid

Fault

-

0x007d0001

8192001

PLC configuration invalid

Fault

-

0x007b0037

8060983

PLC configuration invalid

Fault

-

0x00750006

7667718

PLC configuration invalid

Fault

-

0x006a0012

6946834

Pointer access in impermissible memory area

Fault

-

0x007b004a

8061002

Pole position identification cancelled

Fault

C00640

0x00b8000f

12058639

Position target outside the software limit positions

Quick stop by trouble

C02716/2

0x00910010

9502736

Position value faulty

Fault

-

0x00b80009

12058633

Positive direction of rotation limited

Information

C02716/1

0x00b80001

12058625

Positive limit switch has triggered

Quick stop by trouble

-

0x00b80007

12058631

Positive software limit switch overtravelled

Quick stop by trouble

C02716/2

0x00680014

6815764

Power section has been changed

Information or warning locked if

the hardware type has also

changed.

-

0x0068000f

6815759

Power section incompatible

System fault

-

0x00680001

6815745

Power section is defective

System fault

-

0x00680009

6815753

Power section is defective

System fault

-

0x007b0042

8060994

Power section is defective

System fault

-

0x008c000a

9175050

Project not available

Fault

-

hex

dec

Error message

Response (Lenze setting)

can be set in