9

"CAN on board" system bus

9.10

Implemented CANopen objects | I-1601

358

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1601

The object I-1601 serves to receive parameter data as RPDO2.

• For data telegram assignment, see object

I-1600

.

I-1602

The object I-1602 serves to receive parameter data as RPDO3.

• For data telegram assignment, see object

I-1600

.

I-1603

The object I-1603 serves to receive parameter data as RPDO4.

• For data telegram assignment, see object

I-1600

.

Index:

I-1601

Name:

RPDO2 mapping parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: number of mapped application

objects in PDO

0

0

8 rw

U8

1 ... 8: application object 1 ... 8

0

0

4294967295 rw

U32

Subindex

Meaning

0

Number of mapped objects

1 ... 8

Mapping entries 1 ... 8 for RPDO2

Index:

I-1602

Name:

RPDO3 mapping parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: number of mapped application

objects in PDO

0

0

8 rw

U8

1 ... 8: application object 1 ... 8

0

0

4294967295 rw

U32

Subindex

Meaning

0

Number of mapped objects

1 ... 8

Mapping entries 1 ... 8 for RPDO3

Index:

I-1603

Name:

RPDO4 mapping parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: number of mapped application

objects in PDO

0

0

8 rw

U8

1 ... 8: application object 1 ... 8

0

0

4294967295 rw

U32

Subindex

Meaning

0

Number of mapped objects

1 ... 8

Mapping entries 1 ... 8 for RPDO4