C00344 | can rpdo counter, C00345 | can error, C00346 | can heartbeat activity – Lenze 9400 User Manual

Page 770: C00345, C00346, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00344

770

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00344

C00345

C00346

Parameter | Name:

C00344 | CAN RPDO counter

Data type: UNSIGNED_32

Index: 24231

d

= 5EA7

h

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C00344/1

From software version V1.5

Counter for RPDO1 ... RPDO4

"CAN on board" system bus

C00344/...
C00344/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00345 | CAN error

Data type: UNSIGNED_8

Index: 24230

d

= 5EA6

h

"CAN on board" system bus

Selection list

(read only)

0 No error
1 Guard Event
2 Warning
3 Bus off
4 Sync telegram error
6 CAN controller overflow

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00346 | CAN heartbeat activity

Data type: BITFIELD_32

Index: 24229

d

= 5EA5

h

"CAN on board" system bus: heartbeat protocol

Display area
0x00000000

0xFFFFFFFF

Value is bit-coded:

Bit 0 Heartbeat node 1

... ...

Bit 31 Heartbeat node 32

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1