Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

803

14

Parameter reference

14.2

Parameter list | C00607

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00607

C00610

C00611

Parameter | Name:

C00607 | Resp. to max. speed reached

Data type: UNSIGNED_32

Index: 23968

d

= 5DA0

h

Response if adjustable speed threshold (

C00596

) is reached.

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00610 | Resp. to failure heatsink fan

Data type: UNSIGNED_32

Index: 23965

d

= 5D9D

h

Response if fan speed of heatsink fan is too low.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00611 | Resp. to failure integral fan

Data type: UNSIGNED_32

Index: 23964

d

= 5D9C

h

Response if fan speed of internal fan is too low.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1