I-1006, I-100c, I-100d – Lenze 9400 User Manual

Page 344: 9"can on board" system bus

Advertising
background image

9

"CAN on board" system bus

9.10

Implemented CANopen objects | I-1006

344

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1006

Setting the sync telegram cycle time.

• The cycle time can be selected as "1000" or as an integer multiple of it.
• If "0 μs"

is set (Lenze setting), no sync telegrams are created.

• This object is related to the Lenze code

C00369

.

I-100C

Monitoring time for node guarding.

Node guarding protocol

( 328)

• Time within the NMT slave expects the RTRs from the NMTmaster.
• The "Node Life Time" is the product from "Guard Time" and "Life Time Factor":

Node Life Time = Guard Time (

I-100C

) x Life Time Factor (

I-100D

)

• The "Life Guarding Event" occurs in the NMT slave if this has not been triggered from the NMT

master trough an RTR within the "Node Life Time".

• With "0 ms"

(Lenze setting) monitoring is not supported by the slave.

• This object is related to the Lenze code

C00382

.

I-100D

Life Time Factor for node guarding.

Node guarding protocol

( 328)

• The "Node Life Time" is the product from "Guard Time" and "Life Time Factor":

Node Life Time = Guard Time (

I-100C

) x Life Time Factor (

I-100D

)

• The "Life Guarding Event" occurs in the NMT slave if this has not been triggered from the NMT

master trough an RTR within the "Node Life Time".

• With "0"

(Lenze setting) monitoring is not supported by the slave.

• This object is related to the Lenze code

C00383

.

Index:

I-1006

Name:

Communication cycle period

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Communication cycle period

0 μs

0

μs

65535000 rw

U32

Index:

I-100C

Name:

Guard time

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Guard time

0 ms

0

ms

65535 rw

U16

Index:

I-100D

Name:

Life time factor

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Life time factor

0

0

255 rw

U8