6 traversing range, Traversing range, 4drive interface – Lenze 9400 User Manual

Page 34

Advertising
background image

4

Drive interface

4.1

Machine parameters

34

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.6

Traversing range

The selection of the traversing range ("Unlimited", "Limited", or "Modulo") in the Traversing range

list field (

C02528

) serves to define the machine measuring system.

"Unlimited" traversing range
The drive can rotate continuously in one direction.

• By referencing and activating the software limit positions the traversing range can be limited.
• For positioning with absolute travel command the home position must be known.

[4-5]

Unlimited traversing range, taking the "feed control tape" as an example

"Limited" traversing range
The travel range is limited by positive and negative position limits (mechanical limits/travel range

limit switches/software limit positions).

Limiter

( 502)

• After a defined distance the drive must travel in the opposite direction again.
• For positioning in the limited traversing range the home position must be known.
• The software limit positions are basically monitored with regard to the maximum value range

that can be represented internally (±2

31

increments), even if monitoring has been deactivated

via

C02700

.

• An overflow of the value range results in a loss of the reference information.

[4-6]

Example: Limited traversing range - "spindle drive" (linear axis)

Note!

A change-over of the traversing range results in a loss of the reference information!

M

M

Advertising
This manual is related to the following products: