C00272 | depth - current setp. filter, C00273 | moment of inertia, C00274 | max. acceleration change – Lenze 9400 User Manual

Page 762: C00275 | signal source - speed setpoint, C00273/1, C00273/2, C00272/1, C00272/2, Whic, C00275

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00272

762

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00272

C00273

C00274

C00275

Parameter | Name:

C00272 | Depth - current setp. filter

Data type: UNSIGNED_32

Index: 24303

d

= 5EEF

h

The setting "0 dB" deactivates the current setpoint filter.

Set current setpoint filter (band-stop filter)

Setting range

(min. value | unit | max. value)

0

db

100

Subcodes

Lenze setting

Info

C00272/1

0 db

Depth current setp. filter 1

C00272/2

0 db

Depth current setp. filter 2

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00273 | Moment of inertia

Data type: UNSIGNED_32

Index: 24302

d

= 5EEE

h

Note:

The load moment of inertia must be set with regard to the motor end (i.e. considering the gearbox factors).
Setting range

(min. value | unit | max. value)

0.00

kg cm²

20000000.00

Subcodes

Lenze setting

Info

C00273/1

0.14 kg cm²

Motor moment of inertia

C00273/2

0.00 kg cm²

Load moment of inertia

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00274 | Max. acceleration change

Data type: UNSIGNED_32

Index: 24301

d

= 5EED

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%/ms

400.0 400.0 %/ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00275 | Signal source - speed setpoint

Data type: UNSIGNED_16

Index: 24300

d

= 5EEC

h

Selection list

(Lenze setting printed in bold)

0 SpeedAdd signal
1 Differentiated PosSet signal

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising
This manual is related to the following products: