Limiter

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• If the drive is already outside the permissible travel range and the software limit positions have

been activated, only travel commands that result in the drive moving back into the permissible

travel range can be executed:

[11-27] Example: Permissible traversing direction if software limit positions active

• If the software limit positions are active and a software limit position is passed ("overtravel"):

• The error response "quick stop by trouble" is carried out in the Lenze setting, i.e. the drive is

braked to standstill within the deceleration time set for the quick stop function irrespective

of the setpoint selection. The error response can be parameterised in

C02716/2

.

• The fault message "Pos. SW limit switch overtravelled" or "Neg. SW limit overtravelled" is

entered in the logbook of the controller.

• A corresponding status is output via the LIM_dnState output.
• Depending on the parameterised fault response, the drive cannot traverse until the error has

been acknowledged.

See also:

Manual jog to limit position

( 405)

C02701/2

: Negative software limit position

C02701/1

: Positive software limit position

Traversing in "retracting direction" possible

Traversing opposite to "retracting direction" not possible

Œ

C02701/2



C02701/1

ü

1

0

dnState

Bit 4

Ž

