_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02593

Waiting time - brake activation

Linear value

21982

55DE

E

1

UNSIGNED_32

1000

C02594

Test torque

Linear value

21981

55DD

E

1

INTEGER_32

100

C02595

Permissible angle of rotation

Linear value

21980

55DC

E

1

INTEGER_32

1

C02596

Grinding speed

Linear value

21979

55 db

E

1

INTEGER_32

1

C02597

Accel./decel. time - grinding

Linear value

21978

55DA

E

1

UNSIGNED_32

1000

C02598

Grinding ON time

Linear value

21977

55D9

E

1

UNSIGNED_32

10

C02599

Grinding OFF time

Linear value

21976

55D8

E

1

UNSIGNED_32

10

C02600

Acceleration time feedf. control

Linear value

21975

55D7

E

1

UNSIGNED_32

1000

C02601

Reference for acceleration time of brake

Selection list

21974

55D6

E

1

UNSIGNED_32

1

C02602

Source for feedf. control brake

Selection list

21973

55D5

E

1

UNSIGNED_32

1

C02603

Threshold 1 for opening brake

Linear value

21972

55D4

E

1

INTEGER_32

1

C02604

Threshold 2 for opening brake

Linear value

21971

55D3

E

1

INTEGER_32

1

C02605

Brake test - time

Linear value

21970

55D2

A

3

UNSIGNED_16

1000

C02607

BRK_dnState

Linear value

21968

55D0

E

1

INTEGER_32

1

C02608

BRK_dnTorqueAdd_n

Linear value

21967

55CF

E

1

INTEGER_32

100

C02609

Brake control: Dig. signals

Selection list

21966

55CE

A

10

UNSIGNED_32

1

C02610

Deceleration time for stop

Linear value

21965

55CD

E

1

UNSIGNED_32

1000

C02611

S-ramp time for stop

Linear value

21964

55CC

E

1

UNSIGNED_32

1000

C02612

Ref. for decel. time of stop

Selection list

21963

55CB

E

1

UNSIGNED_32

1

C02616

STP_dnState

Linear value

21959

55C7

E

1

INTEGER_32

1

C02617

STP_bStopActive

Selection list

21958

55C6

E

1

UNSIGNED_32

1

C02619

Quick stop: Dig. signals

Selection list

21956

55C4

A

5

UNSIGNED_32

1

C02620

Manual jog: Speed 1

Linear value

21955

55C3

E

1

INTEGER_32

10000

C02621

Manual jog: Speed 2

Linear value

21954

55C2

E

1

INTEGER_32

10000

C02622

Manual jog: Acceleration

Linear value

21953

55C1

E

1

INTEGER_32

10000

C02623

Manual jog: Deceleration

Linear value

21952

55C0

E

1

INTEGER_32

10000

C02624

Manual jog: S-ramp time

Linear value

21951

55BF

E

1

UNSIGNED_32

1000

C02625

Manual jog: Step size

Linear value

21950

55BE

E

1

INTEGER_32

10000

C02626

Manual jog: Index stop position

Linear value

21949

55BD

A

16

INTEGER_32

1

C02627

Manual jog: Selected stop position

Linear value

21948

55BC

A

16

INTEGER_32

10000

C02637

MAN_dnSpeedOverride_n

Linear value

21938

55B2

E

1

INTEGER_32

100

C02638

Manual jog: Status

Linear value

21937

55B1

E

1

INTEGER_32

1

C02639

Manual jog: Dig. signals

Selection list

21936

55B0

A

9

UNSIGNED_32

1

C02640

Homing mode

Selection list

21935

55AF

E

1

UNSIGNED_32

1

C02641

Action after detect home position

Selection list

21934

55AE

E

1

UNSIGNED_32

1

C02642

Home position

Linear value

21933

55AD

E

1

INTEGER_32

10000

C02643

Homing: Target position

Linear value

21932

55AC

E

1

INTEGER_32

10000

C02644

Homing: Speed 1

Linear value

21931

55AB

E

1

INTEGER_32

10000

C02645

Homing: Acceleration 1

Linear value

21930

55AA

E

1

INTEGER_32

10000

C02646

Homing: Speed 2

Linear value

21929

55A9

E

1

INTEGER_32

10000

C02647

Homing: Acceleration 2

Linear value

21928

55A8

E

1

INTEGER_32

10000

C02648

Homing: S-ramp time

Linear value

21927

55A7

E

1

INTEGER_32

1

C02649

Homing: Torque limit

Linear value

21926

55A6

E

1

INTEGER_32

100

C02650

Homing: Blocking time

Linear value

21925

55A5

E

1

UNSIGNED_32

1000

C02651

Homing: TP configuration

Linear value

21924

55A4

E

1

UNSIGNED_32

1

C02652

Ref. pos. after mains switching

Selection list

21923

55A3

E

1

UNSIGNED_32

1

C02653

Max. rot. ang. aft. mns. swtch.

Linear value

21922

55A2

E

1

INTEGER_32

1

C02655

HM_dnSpeedOverride_n

Linear value

21920

55A0

E

1

INTEGER_32

100

C02656

Actual position (homing)

Linear value

21919

559F

E

1

INTEGER_32

10000

C02657

HM_dnState

Linear value

21918

559E

E

1

INTEGER_32

1

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH