C01122 | sync phase position, C01123 | sync tolerance, C01122 – Lenze 9400 User Manual

Page 833: C01123, Is inc, Position, Into t, E is increased, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

833

14

Parameter reference

14.2

Parameter list | C01122

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01122

C01123

Parameter | Name:

C01122 | Sync phase position

Data type: UNSIGNED_32

Index: 23453

d

= 5B9D

h

The phase position defines the zero point of time for the application relating to the synchronisation signal (bus

cycle). Since PDO processing is integrated in the system part of the application, the instant of the PDO acceptance

also changes if the phase position is changed.

• If 0 is set, the application is started together with the synchronisation signal.

• If a value > 0 is set, the application starts by the set time interval before the synchronisation signal arrives (the

phase position acts negatively).

Example: If the phase position is set to 400 μs, the system part of the application starts 400 μs before the

synchronisation signal arrives.

From software version V3.0:

The effect of the sync phase position can be affected by the application cycle set in

C01130

. For the Lenze setting of

C01130

the behaviour remains as before.

"CAN on board" system bus: sync telegram

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

64000 400 μs

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01123 | Sync tolerance

Data type: UNSIGNED_32

Index: 23452

d

= 5B9C

h

Time slot for monitoring the synchronisation signal via the LS_SyncInput system block

• If the last synchronisation signal amounted to approx. the expected value within this time slot, the

SYNC_bSyncInsideWindow output of the LS_SyncInput system block is set to TRUE.

• This setting does not affect the synchronisation process.

"CAN on board" system bus: sync telegram

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

1000 0 μs

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1