9"can on board" system bus – Lenze 9400 User Manual

Page 326

Advertising
background image

9

"CAN on board" system bus

9.7

Parameter data transfer

326

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Telegram 3 to the drive: Request of the 2nd data block

Response message 3 from the drive: Transmission of the 2nd data block including end identifier

Identifier

User data

1st byte

2nd byte 3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Data 1

Data 2

Data 3

Data 4

Data 5

Data 6

Data 7

0x060C

0x70

0x00

0x00

0x00

0x00

0x00

0x00

0x00

Explanations on telegram 3 to the drive
Command

= 0x70 = "Read segment request" (request: read data block)

• Bit 4 = 1 (toggle bit)

Identifier

User data

1st byte

2nd byte 3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Data 1

Data 2

Data 3

Data 4

Data 5

Data 6

Data 7

0x058C

0x17

0x30

0x2E

0x30

0x30

0x00

0x00

0x00

0

asc

.

asc

0

asc

0

asc

-

-

-

Explanations on telegram 3 from the drive
Command

= 0x17 = 00010111

bin

:

• Bit 0 = 1 (end of transmission)

• Bit 1 ... bit 3 = 011

bin

(3 bytes do not contain any data)

• Bit 4 = 1 (toggle bit)

Influence of the final bit and the residual data length on the transmission command

• The end of transmission is signalled via the set final bit 0.

• Bits 1 ... 3 reveal the number of bytes that do not contain any data anymore.

* Toggle bit

Data 1 ... 7

= "0.00" (ASCII representation)

The result of the data block transmission is: "01.00.00.00"