Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Structure of the I

2

xt monitoring

The introduction of a two-component model with two time constants (one for the winding and the

other for the housing/laminated core) serves to display the thermal behaviour of the motor up to

500% of the rated current:

[5-34] Structure of the motor monitoring

Calculation with only one time constant
With

C01195

= "0 %" the time constant for the winding is not considered and the thermal model is

only calculated with the time constant set for the housing/laminated core.

• The setting

C01195

= "0 %" is reasonable if for example the two time constants are not known.

• The calculation simplified due to this setting corresponds to the calculation in the previous

Lenze devices (e.g. 9300 servo inverter or ECS).

Thermal utilisation of the motor in [%]

k

1

1

(1 + p

)

t

1

k

2

1

(1 + p

)

t

2

Œ

I

act motor

I

perm motor

(n)

2

Parameter

Setting

I

act motor

Actual motor current

-

I

perm motor

(n)

Permissible motor current (speed-dependent)

-

τ

1

Therm. time constant coil

C00128/1

k

1

Percentage of the winding in the final temperature

C01195

τ

2

Therm. time constant plates

C00128/2

k

2

Percentage of the steel plates in the final temperature

100 % -

C01195