Note!

For the operation with the motor brake control module:

• For single-axis controllers (Single Drive) the control (release) of the motor holding

brake is only possible if both the DC-bus voltage and a 24-V supply voltage are

available for the motor brake control!

• For multi-axis controllers (Multi Drive) the motor holding brake can also be released

without a DC-bus voltage.

For the encoderless motor control types

(from software version V3.0)

the following

applies:
The operation of vertical drives/hoists is

• only supported up to 55 kW by the V/f control!
• not supported by the sensorless vector control!

When the V/f control or sensorless vector control are selected, standstill monitoring is

always switched off.