Implemented CANopen objects | I-1802

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1802

Communication parameter for sending process data via TPDO3

• For assignment of the data telegram see object

I-1800

.

I-1803

Communication parameter for the transmission of process data via TPDO4

• For assignment of the data telegram see object

I-1800

.

Index:

I-1802

Name:

TPDO3 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by TPDO

0x380 + node ID

0

4294967295 rw

U32

2: transmission type

254

0

255 rw

U8

3: inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: reserved

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

TPDO3 identifier

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x380 + node ID

C00320/3

2

TPDO transmission type according to DS301 V4.02

Transmission type ( 308)

C00322/3

3

Minimum time between sending two identical TPDOs

(see DS301 V4.02).

C00324/3

5

Cycle time for PDO transmission with transmission type

"254".

C00356/3

Index:

I-1803

Name:

TPDO4 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by TPDO

0x480 + node ID

0

4294967295 rw

U32

2: transmission type

254

0

255 rw

U8

3: inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: reserved

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

Identifier TPDO4

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x480 + node ID

C00320/4

2

TPDO transmission type according to DS301 V4.02

Transmission type ( 308)

C00322/4

3

Minimum time between sending two identical TPDOs

(see DS301 V4.02).

C00324/4

5

Cycle time for PDO transmission with transmission type

"254".

C00356/4