11 basic drive functions – Lenze 9400 User Manual

Page 531

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

531

11

Basic drive functions

11.12

Brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Waiting time for status monitoring
Every time the brake status changes, the waiting time set in

C02591

is awaited after the brake

opening or brake closing time has elapsed, before the monitoring of the motor brake control

module and the status input BRK_bBrakeApplied (if activated via

C02583

) and the standstill

monitoring function are switched active again.

• During the "Closing the brake" process, a mechanical contact must signal the "brake closed"

state after the waiting time has elapsed.

• During the "Releasing the brake" process, a mechanical contact must signal the "brake released"

state after the waiting time has elapsed.

Tip!
The additional waiting time is based on the fact that during the state change of the brake

also state changes with regard to the monitored signals within the brake logic can occur,

e. g. by bouncing the microswitch on the brake, or activation of the short circuit threshold

within the motor brake control module due to discharge current peaks when the brake

voltage is switched on. These state changes result in the activation of the monitoring

function, although no stationary fault is pending.

[11-37] Definition of the waiting time for status monitoring

 Brake status (with bouncing or transient response)

 Active status monitoring

C02589

: Brake closing time

C02590

: Brake opening time

C02591

: Waiting time - status monit.

• The waiting time in

C02591

must be set so

that bouncing of a feedback contact and

the transient response of the brake current

monitoring will be suppressed completely.

• If no corresponding feedback takes place

after the waiting time has elapsed:

• The error output BRK_bError is set to

TRUE until the next trigger attempt

starts.

• The error response "Quick stop by

trouble" is activated.

• The error message "Brake status error" is

entered into the logbook.

t

Ž

t

t

0

1

Œ



Ž

t

t

Stopping/Standstill

BRK_bReleaseBrakeOut

I

BRK

Advertising