Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

347

9

"CAN on board" system bus

9.10

Implemented CANopen objects | I-1014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1014

If a communication error or an internal error of the communication module or the controller occurs

or is acknowledged (e. g. "trouble"), an error message is sent via the system bus. For each error, the

telegram is interrupted once. By means of bit 31 this function can be activated or deactivated.

• This object is related to the Lenze code

C00391

.

[9-17] Data telegram assignment

I-1015

Time which must elapse after an error message (

I-1014

) has been transmitted before further error

messages can be sent via the bus.

• The entered value multiplied by "0.1" gives the delay time in [ms]. The values are automatically

rounded up to whole values in [ms].

• This object is related to the Lenze code

C00392

.

Index:

I-1014

Name:

COB-ID EMCY

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: COB-ID EMCY

0x80 + node ID

0

4294967295 rw

U32

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0/1

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported. Bit 11 ... bit 29 must be set to "0".

Bit

Setting

Bit 31

0 Emergency object is valid.
1 Emergency object is invalid.

Note!

The identifier can only be changed in the "emergency object invalid" status (bit 31 = 1).

Index:

I-1015

Name:

Inhibit time EMCY

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: inhibit time EMCY

0

0

0.1 ms

65535 rw

U32