11 basic drive functions – Lenze 9400 User Manual

Page 381

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

381

11

Basic drive functions

11.1

General information

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

The following applies from software version V7.0 onwards:

• The start acceleration is reduced with the maximum jerk of the old or new basic function.

Transition of a profile-generating to a profile-generating basic function
The corresponding jerk results from the profile data:

Transition of a non-profile-generating to a profile-generating basic function

• The jerk of the profile-generating basic function results from the profile data:

• Since a non-profile-generating basic function has no defined jerk, a "transition jerk" is used

which results from the reference acceleration and the reference S-ramp time parameterised in

C02545

.

• With a Lenze setting

C02545

= 0.001 s, a maximum jerk occurs, i.g. the start acceleration is

reduced in one cycle (1 ms).

• The setting

C02545

= 0.000 s results in a compatible behaviour lower than V7.0.

Tip!
Profile-generating basic functions are:

"

Stop

", "

Manual jog

", "

Homing

", "

Positioning

"

Non-profile-generating basic functions are:

"

Quick stop

", "

Position follower

", "

Speed follower

", "

Torque follower

"

Jerk

Profile acceleration/deceleration

Verschliffzeit

-------------------------------------------------------------------------------------

=

Jerk

Profile acceleration/deceleration

Verschliffzeit

-------------------------------------------------------------------------------------

=

Transition jerk

Bezugsacceleration

Bezugsverschliffzeit

----------------------------------------------------------

C00011 / 1 ms