C01124 | sync-pll increment, C01124, G in – Lenze 9400 User Manual

Page 834: Defines th, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C01124

834

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01124

C01125

C01126

Parameter | Name:

C01124 | Sync-PLL increment

Data type: UNSIGNED_8

Index: 23451

d

= 5B9B

h

When the cycle times of the synchronisation signal and the phase control loop (PLL) differ, this setting defines the

increment to be used to readjust the phase control loop.

• If the system bus (CANopen) is used as the synchronisation source, the recommended value is 109 ns.

"CAN on board" system bus: sync telegram

Selection list

(Lenze setting printed in bold)

1 7 ns
2 15 ns
3 23 ns
4 31 ns
5 39 ns
6 46 ns
7 54 ns
8 62 ns
9 70 ns

10 78 ns
11 85 ns
12 93 ns
13 101 ns
14 109 ns
15 117 ns
16 125 ns
17 132 ns
18 140 ns
19 148 ns
20 156 ns
21 164 ns
22 171 ns
23 179 ns
24 187 ns
25 195 ns
26 203 ns
27 210 ns

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01125 | Service code

Data type: UNSIGNED_32

Index: 23450

d

= 5B9A

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C01126 | Service code

Data type: UNSIGNED_32

Index: 23449

d

= 5B99

h

This code is for device-internal use only and must not be written to by the user!

Advertising
This manual is related to the following products: