Parameter list | C00464

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00464

C00465

C00466

C00467

C00468

Parameter | Name:

C00464 | Keypad: Mode

Data type: UNSIGNED_16

Index: 24111

d

= 5E2F

h

From software version V5.0

Definition of the mode in which the keypad attached is to be activated.

• If both

keypad versions (V1.0 and V2.0) are used, the Lenze setting is to be maintained.

• If only the new keypad V2.0 is used, the initialisation time of the keypad can be reduced by changing over to

mode 2. Furthermore mode 2 supports greater future keypad files.

Note: If mode 2 is selected, the keypad V1.0 can no longer be operated on the controller!
Selection list

(Lenze setting printed in bold)

Info

0 Mode 1

For keypad V1.0 and V2.0

1 Mode 2

Only for keypad V2.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00465 | Keypad: Timeout welcome screen

Data type: UNSIGNED_8

Index: 24110

d

= 5E2E

h

Selection list

(Lenze setting printed in bold)

0 Never show welcome screen
5 5 min

15 15 min
30 30 min
60 60 min

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00466 | Keypad: Default parameter

Data type: UNSIGNED_16

Index: 24109

d

= 5E2D

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00467 | Keypad: Default welcome screen

Data type: UNSIGNED_8

Index: 24108

d

= 5E2C

h

Selection list

(Lenze setting printed in bold)

0 Main menu
1 Parameter list

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00468 | Service code

Data type: UNSIGNED_8

Index: 24107

d

= 5E2B

h

This code is for device-internal use only and must not be written to by the user!