Test step 4

• After mains switching and an overload of the rated motor current (

C00088

), the I²xt motor

monitoring has to be tripped faster than before mains switching with the same overload.

From software version V11.0:

Initial value of the thermal model of the I²xt motor monitoring:

C01197

> 0 %.

Example for a UL 508C-compliant total parameterisation of the I²xt motor monitoring of the device:

Code

Setting

Info

C00120

100 %

Switch-off threshold of motor overload protection (I²xt)

C00128/2

11.8 min

Thermal time constant - laminated core/housing

C01195

0 %

Percentage of the winding in the final temperature

C01196/1

0 %

Speed = 0 (standstill)

C01196/2

< 100 %

Permissible motor torque at standstill

C01196/3

20 Hz * (

C00089

/

C00087

)

Speed n

2

from which on the torque must be reduced

C01196/4

100 %

Permissible motor torque at speed n

2

(torque reduction)

C01196/5

100 %

Rated speed

C01196/6

100 %

Permissible motor torque at rated speed

C01196/7

100 %

Rated speed

C01196/8

100 %

Speed above rated speed

C01197

> 0 %

Initial value of the thermal model of the I²xt motor

monitoring