C00323 | can rpdox rx mode, C00324 | can tpdox delay time, C00323/1 – Lenze 9400 User Manual

Page 768: C00324/1, C00323/2, C00323/3, C00323/4, C00324/2, C00324/3, C00324/4

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00323

768

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00323

C00324

C00325

C00326

C00327

Parameter | Name:

C00323 | CAN RPDOx Rx mode

Data type: UNSIGNED_8

Index: 24252

d

= 5EBC

h

RPDO transmission type according to DS301 V4.02

• For the RPDO serves as monitoring setting in the case of sync-controlled PDOs.

• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled

device-profile-specific) are supported.

• The basic PDO setting is "254" (event-controlled).

• Mapping of the CANopen objects

I-1400/2

...

I-1403/2

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C00323/1

254

Transmission mode for RPDO1 ... RPDO4

C00323/...
C00323/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00324 | CAN TPDOx delay time

Data type: UNSIGNED_16

Index: 24251

d

= 5EBB

h

TPDO inhibit time according to DS301 V4.02

• Minimum time between the transmission of two identical TPDOs.

• The delay time is entered in 1/10 ms and automatically rounded to full milliseconds by the code.

• Mapping of the CANopen objects

I-1800/3

...

I-1803/3

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

1/10 ms

65535

Subcodes

Lenze setting

Info

C00324/1

0 1/10 ms

Delay time for TPDO1 ... TPDO4

C00324/...
C00324/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00325 | Service code

Data type: UNSIGNED_8

Index: 24250

d

= 5EBA

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00326 | Service code

Data type: UNSIGNED_8

Index: 24249

d

= 5EB9

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00327 | Service code

Data type: BITFIELD_32

Index: 24248

d

= 5EB8

h

This code is for device-internal use only and must not be written to by the user!

Advertising