Motor data are inconsistent [0x007b0003, Motor: phase resistance too high [0x007b0004, 0x007b0003 – Lenze 9400 User Manual

Page 648: 0x007b0001, 0x007b0002, 0x007b0006, 0x007b0004, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

648

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Motor: Calculated motor impedance unrealistic [0x007b0001]

Motor: Calculated mutual inductance unrealistic [0x007b0002]

Motor data are inconsistent [0x007b0003]

Motor: Phase resistance too high [0x007b0004]

Motor: Device current too low for rated magnetisation [0x007b0006]

Module ID (decimal)

Error ID (decimal)

123: Motor control

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty motor parameterisation.

Check motor parameters.

Module ID (decimal)

Error ID (decimal)

123: Motor control

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty motor parameterisation.

Check motor parameters.

Module ID (decimal)

Error ID (decimal)

123: Motor control

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty motor parameterisation.

Check motor parameters.

Module ID (decimal)

Error ID (decimal)

123: Motor control

4

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty motor parameterisation.

Check motor parameters.

Module ID (decimal)

Error ID (decimal)

123: Motor control

6

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Controller current is too low for rated magnetisation, i.e.

the controller cannot energise the motor sufficiently.

Check drive dimensioning.