257

6

Encoder evaluation

6.3

Parameter setting

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the parameters:

Parameter

Info

Lenze setting

Value Unit

C00422

Encoder type

SSI encoder

C00423

SSI encoder: Bit rate

400 kbps

C00424

SSI encoder: Data word length

24 Bit

C00435/1

SSI enc.: Partword 1 start

0

C00436/1

SSI enc.: Partword 1 length

24

C00437/1

SSI enc.: Partword 1 coding

gray coded

C00490

Position encoder selection

Encoder on X8

C00495

Motor encoder selection

Resolver on X7

C02522

Gearbox factor numerator: position encoder

84823

C02523

Gearbox factor denominator: position encoder

84820

C02524

Feed constant

848.23 mm

C02570

Position control structure

Position controller is active

C04276

Position offset at FDB_dnPosOffset_p

100 mm

C05271

32-bit encoder signal

C005273

Single turn resolution

8482 Steps/rev

C05274

Resolution Multiturn

60 Rev