Diagnostics & fault analysis

13.3

Drive diagnostics via keypad/bus system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.3

Drive diagnostics via keypad/bus system

Keypad display of the controller status

Display parameters
The parameters listed in the following tables serve to query current states and actual values of the

controller for diagnostic purposes, e.g. by using the keypad, a bus system or the »Engineer« (with an

online connection to the controller).

• These parameters are listed in the »Engineer« parameter list and the keypad in the Diagnostics

category.

• A detailed description of these parameters can be found in the chapter "

Parameter reference

".

( 713)

• If the keypad on the front of the controller is connected to the

diagnostic interface X6, the status of the controller is shown

via different icons on the LCD display in the area .

Icon

Meaning

Note

Controller is ready for operation.

Controller is enabled.

Application in the controller is stopped.

Quick stop active

Controller is inhibited.

The power outputs are inhibited.

Controller is ready to switch on.

Speed controller 1 at the limit.

The drive is torque-controlled.

Set current limit has been exceeded in motor

or generator mode.

Pulse inhibit active

The power outputs are inhibited.

System fault active

Fault active

Trouble active

Quick stop by trouble active

Warning active

Parameter

Display

C00183

Device status

C00166

Error description

C00168

Error number

C00051

Actual speed [rpm]

C00052

Motor voltage

C00054

Motor current