Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1016

Monitoring time for the nodes 1 ... 32 to be monitored via heartbeat.

Heartbeat protocol

( 334)

• The parameterised time is rounded down to an integer multiple of 5 ms and must have a greater

value than the heartbeat producer time of the node to be monitored.

[9-18] Data telegram assignment

I-1017

Time interval for the transmission of the heartbeat telegram to one or several

consumers.

Heartbeat protocol

( 334)

• The parameterised time is rounded down to an integer multiple of 5 ms.
• The heartbeat telegram is automatically sent as soon as a time > 0 ms is entered. In this case,

the "node guarding" monitoring function is deactivated.

• This object is related to the Lenze code

C00381

.

Index:

I-1016

Name:

Consumer heartbeat time

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

32

- (read access only)

ro

U32

1 ... 32: consumer heartbeat time

0

0

4294967295 rw

U32

Subindex

Meaning

Lenze code

0

Number of nodes to be monitored

1 ... 32

Node-ID and heartbeat time of the node 1 ... 32 to be

monitored

C00385/1...32

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31 ... bit 24

Bit 23 ... bit 16

Bit 15 ... bit 0

0

(reserved)

Node ID

Heartbeat time

in [ms]

Index:

I-1017

Name:

Producer heartbeat time

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Producer heartbeat time

0

0

ms

65535 rw

U32